Chernobyl Legacy Reportage By Paul Fusco
|
After a period, a more or less stable state at a power level 200 MW was achieved, and preparation for the experiment continued. As part the test plan, at 1:05 a.m. on 26 April extra water pumps were activated, increasing the water flow. The increased coolant flow rate through the reactor produced an increase in the inlet coolant temperature the reactor core, which now more closely approached the nucleate boiling temperature water, and reducing the safety margin. The flow exceeded the allowed limit at 1:19 a.m. At the same time the extra water flow lowered the overall core temperature and reduced the existing steam voids in the core. Since water also absorbs neutrons (and the higher density liquid water makes it a better absorber than steam), turning on additional pumps decreased the reactor power still further. This prompted the operators to remove the manual control rods further to maintain power.
All these actions led to an extremely unstable reactor configuration. Nearly all the control rods were removed, which would limit the value the safety rods when initially inserted in a scram condition. Further, the reactor coolant had reduced boiling, but had limited margin to boiling, so any power excursion would produce boiling, reducing neutron absorption by the water. The reactor was in an unstable configuration that was clearly outside the safe operating envelope established by the designers.
|
|